30 CFR 75.826: High-voltage trailing cables.
Where this section sits in the code
- Title 30—Mineral Resources
- CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
- SUBCHAPTER O—COAL MINE SAFETY AND HEALTH
- PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES
- Subpart I—Underground High-Voltage Distribution
High-voltage trailing cables must:
(a) Meet existing trailing cable requirements and the approval requirements of the high-voltage continuous mining machine; and
(b) Meet existing ground-check conductor requirements (§ 75.804) or have a stranded center ground-check conductor not smaller than a No. 16 A.W.G.