33 CFR 155.410: Pumping, piping and discharge requirements for non-oceangoing ships of 100 gross tons and above.
Where this section sits in the code
- Title 33—Navigation and Navigable Waters
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER O—POLLUTION
- PART 155—OIL OR HAZARDOUS MATERIAL POLLUTION PREVENTION REGULATIONS FOR VESSELS
- Subpart B—Vessel Equipment
(a) No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless:
(1) The ship has at least one pump installed to discharge oily mixtures through a fixed piping system to a reception facility;
(2) The piping system required by this section has at least one outlet that is accessible from the weather deck;
(3) Each outlet required by this section has a shore connection that is compatible with reception facilities in the ship's area of operation; and
(4) The ship has a stop valve for each outlet required by this section.
(b) Paragraph (a) of this section does not apply to a ship that has approved oily-water separating equipment for the processing of oily mixtures from bilges or fuel oil tank ballast.
(c) This section does not apply to a fixed or floating drilling rig or other platform.