40 CFR 411.12: Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 411—CEMENT MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart A—Nonleaching Subcategory

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristic Effluent limitations (maximum for any 1 day)

Metric units (kg/kkg of product)

TSS 0.005.

Temperature (heat) Not to exceed 3 °C rise above inlet temperature.

pH Within the range 6.0 to 9.0.

English units (lb/1,000 lb of product)

TSS 0.005.

Temperature (heat) Not to exceed 3 °C rise above inlet temperature.

pH Within the range 6.0 to 9.0.