40 CFR 415.472: Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
- PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY
- Subpart AU—Nickel Salts Production Subcategory
(a) Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart and producing nickel sulfate, nickel chloride, nickel nitrate, or nickel fluoborate must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per/1,000 lb) of product
TSS 0.096 0.032
Nickel (T) 0.0060 0.0020
pH (1) (1)
1 Within the range 6.0 to 9.0.
(b) Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart and producing nickel carbonate must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Subpart AU—Nickel Carbonate
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (or pounds per/1,000 lb) of product
TSS 17. 5.6
Nickel (T) 1.1 0.35
pH (1) (1)
1 Within the range 6.0 to 9.0.
Collected 2026-08-27T02:26:04Z. Source file · JSON