40 CFR 418.33: Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
- PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY
- Subpart C—Urea Subcategory
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
(a) The following limitations constitute the maximum permissible discharge for urea manufacturing operations in which urea is produced as a solution product:
Effluent characteristics Effluent limitations (mg/l)
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Ammonia (as N) 0.53 0.27
Organic nitrogen (as N) 0.45 0.24
Note: Metric units: Kilogram/1,000 kg of product; English units: Pound/1,000 lb of product.
(b) The following limitations constitute the maximum permissible discharge for urea manufacturing operations in which urea is prilled or granulated:
Effluent characteristics Effluent limitations (mg/l)
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Ammonia (as N) 0.53 0.27
Organic nitrogen (as N) .86 .46
Note: Metric units: Kilogram/1,000 kg of product; English units: Pound/1,000 lb of product.