40 CFR 420.122: Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart L—Hot Coating Subcategory

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

(a) Galvanizing, terne coating, and other coatings—(1) Strip, sheet, and miscellaneous products.

Subpart L

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.175 0.0751

O&G 0.0751 0.0250

Lead 0.00113 0.000376

Zinc 0.00150 0.000500

Chromium (hexavalent) 1 0.000150 0.0000501

pH (2) (2)

1 The limitations for hexavalent chromium shall apply only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

(2) [Reserved]

(b) Galvanizing and other coatings—(1) Wire products and fasteners.

Subpart L

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.701 0.300

O&G 0.300 0.100

Lead 0.00451 0.00150

Zinc 0.00601 0.00200

Chromium (hexavalent) 1 0.000600 0.000200

pH (2) (2)

1 The limitations for hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

(2) [Reserved]

(c) Fume scrubbers.

Subpart L

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg per day

TSS 38.1 16.3

O&G 16.3 5.45

Lead 0.245 0.0819

Zinc 0.327 0.109

Chromium (hexavalent) 1 0.0327 0.0109

pH (2) (2)

1 The limitations for hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.