GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR 420.127: Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology (BCT).

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart L—Hot Coating Subcategory

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology.

(a) Galvanizing, terne coating, and other coatings—(1) Strip, sheet, and miscellaneous products.

Subpart L

Pollutant or pollutant property BCT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.175 0.0751

O&G 0.0751 0.0250

pH (1) (1)

1 Within the range of 6.0 to 9.0.

(2) [Reserved]

(b) Galvanizing and other coatings—(1) Wire products and fasteners.

Subpart L

Pollutant or pollutant property BCT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.701 0.300

O&G 0.300 0.100

pH (1) (1)

1 Within the range of 6.0 to 9.0.

(2) [Reserved]

(c) Fume scrubbers.

Subpart LBAT Effluent Limitations

Pollutant or pollutant property BCT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kilograms per day

TSS 38.1 16.3

O&G 16.3 5.45

pH (1) (1)

1 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.