40 CFR 424.12: Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory

Except as provided in §§ 125.30 through 125.32, and subject to the provisions of paragraph (a) of this section, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristic Effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—

Metric units (kg/Mwh)

TSS 0.319 0.160

Chromium total .006 .0032

Chromium VI .0006 .0003

Manganese total .064 .032

pH (1) (1)

English units (lb/Mwh)

TSS .703 .352

Chromium total .014 .007

Chromium VI .0014 .0007

Manganese total .141 .070

pH (1) (1)

1 Within the range 6.0 to 9.0.