The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristic Effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—

Metric units (kg/Mwh)

TSS 0.024 0.012

Chromium total .0008 .0004

Chromium VI .00008 .00004

Manganese total .008 .0039

pH (1) (1)

English units (lb/Mwh)

TSS .052 .026

Chromium total .0017 .0009

Chromium VI .0002 .0001

Manganese total .017 .0086

pH (1) (1)

1 Within the range 6.0 to 9.0.