40 CFR 430.46: Pretreatment standards for existing sources (PSES).
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
- PART 430—THE PULP, PAPER, AND PAPERBOARD POINT SOURCE CATEGORY
- Subpart D—Dissolving Sulfite Subcategory
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must: comply with 40 CFR part 403; and achieve the following pretreatment standards for existing sources (PSES) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides. PSES must be attained on or before July 1, 1984:
Subpart D
[PSES for dissolving sulfite pulp facilities where nitration, viscose, or cellophane grade pulps are produced]
Pollutant or pollutant property Maximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of product a
Pentachlorophenol (0.011)(66.0)/y 0.0030
Trichlorophenol (0.082)(66.0)/y 0.023
y = wastewater discharged in kgal per ton of product.
a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.
Subpart D
[PSES for dissolving sulfite pulp facilities where acetate grade pulp is produced]
Pollutant or pollutant property Maximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of product a
Pentachlorophenol (0.011)(72.7)/y 0.0033
Trichlorophenol (0.082)(72.7)/y 0.025
y = wastewater discharged in kgal per ton of product.
a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.