GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR 463.22: Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 463—PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY
  5. Subpart B—Cleaning Water Subcategory

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the effluent limitations guidelines (i.e., mass of pollutant discharged) representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available, which are calculated by multiplying the average process water usage flow rate for the cleaning water processes at a point source times the following pollutant concentrations:

Subpart B

[Cleaning water]

Concentration used to calculate BPT effluent limitations

Pollutant or pollutant property Maximum for any 1 day (mg/l) Maximum for monthly average (mg/l)

BOD5 49 22

Oil and grease 71 17

TSS 117 36

pH (1) (1)

1 Within the range of 6.0 to 9.0 at all times.

The permit authority will obtain the average process water usage flow rate for the cleaning water processes from the permittee.