40 CFR 463.34: New source performance standards.

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 463—PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY
  5. Subpart C—Finishing Water Subcategory

(a) NSPS for bis(2-ethylhexyl) phthalate, di-n-butyl phthalate, and dimethyl phthalate are reserved.

(b) Any new source subject to this subpart must achieve performance standards (i.e., mass of pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the finishing water processes at a new source times the following pollutant concentrations:

Subpart C

[Finishing water]

Concentration used to calculate NSPS

Pollutant or pollutant property Maximum for any 1 day (mg/l) Maximum for monthly average (mg/l)

TSS 130 37

pH (1) (1)

1 Within the range of 6.0 to 9.0 at all times.

The permit authority will obtain the average process water usage flow rate for the new source finishing water processes from the permittee.