GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR 60.3067: How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste?

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
  5. Subpart FFFF—Emission Guidelines and Compliance Times for Other Solid Waste Incineration Units

(a) Use EPA Method 9 of Appendix A to this part or ASTM D7520-16 (incorporated by reference, see § 60.17), to determine compliance with the opacity limitation.

(b) Conduct an initial test for opacity as specified in § 60.8 within 180 days after the final compliance date in table 1 of this subpart.

(c) After the initial test for opacity, conduct annual tests no more than 12 months following the date of your previous test.

(d) If the air curtain incinerator has been out of operation for more than 12 months following the date of your previous test, then you must conduct a test for opacity upon startup of the unit.

Collected 2026-08-27T02:26:04Z. Source file · JSON

Browse this collection