40 CFR 62.14740a: a What is an air curtain incinerator?
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 62—APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS
- Subpart IIIa—Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That Commenced Construction On or Before June 4, 2010, and Have Not Been Modified or Reconstructed Since August 7, 2013
(a) An ACI operates by forcefully projecting a curtain of air across an open chamber or open pit in which combustion occurs. Incinerators of this type can be constructed above or below ground and with or without refractory walls and floor. Air curtain incinerators are not to be confused with conventional combustion devices with enclosed fireboxes and controlled air technology such as mass burn, modular, and fluidized bed combustors.
(b) Air curtain incinerators that burn only the materials listed in paragraphs (b)(1) through (3) of this section are only required to meet the requirements under § 62.14770a, this section, and §§ 62.14745a through 62.14765a:
(1) One hundred (100) percent wood waste;
(2) One hundred (100) percent clean lumber; and
(3) One hundred (100) percent mixture of only wood waste, clean lumber, and/or yard waste.
Collected 2026-08-27T02:26:04Z. Source file · JSON