GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR Appendix A1 to Subpart F of Part 82: Appendix A1 to Subpart F of Part 82—Generic Maximum Contaminant Levels

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 82—PROTECTION OF STRATOSPHERIC OZONE
  5. Subpart F—Recycling and Emissions Reduction

Contaminant Reporting units

Air and Other Non-condensables 1.5% by volume @ 25 °C (N/A for refrigerants used in low-pressure appliances 1).

Water 10 ppm by weight 20 ppm by weight (for refrigerants used in low-pressure appliances 1).

Other Impurities Including Refrigerant 0.50% by weight.

High boiling residue 0.01% by volume.

Particulates/solids visually clean to pass.

Acidity 1.0 ppm by weight.

Chlorides (chloride level for pass/fail is 3ppm) No visible turbidity.

1 Low-pressure appliances means an appliance that uses a refrigerant with a liquid phase saturation pressure below 45 psia at 104 °F.

Blend Compositions (Where Applicable)

Nominal composition (by weight%) Allowable composition (by weight%)

Component constitutes 25% or more ±2.0

Component constitutes less than 25% but greater than 10% ±1.0

Component constitutes less than or equal to 10% ±0.5

Collected 2026-08-27T02:26:04Z. Source file · JSON