GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR Table 1 to Subpart HHHHH of Part 63: Table 1 to Subpart HHHHH of Part 63—Emission Limits and Work Practice Standards for Process Vessels

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
  5. Subpart HHHHH—National Emission Standards for Hazardous Air Pollutants: Miscellaneous Coating Manufacturing

Table 1 to Subpart HHHHH of Part 63—Emission Limits and Work Practice Standards for Process Vessels

[As required in § 63.8005, you must meet each emission limit and work practice standard in the following table that applies to your process vessels.]

For each . . . You must . . . And you must . . .

1. Portable process vessel at an existing source a. Equip the vessel with a cover or lid that must be in place at all times when the vessel contains a HAP, except for material additions and sampling Nonapplicable.

2. Stationary process vessel at an existing source a. Equip the vessel with a cover or lid that must be in place at all times when the vessel contains a HAP, except for material additions and sampling; or b. Equip the vessel with a tightly fitting vented cover or lid that must be closed at all times when the vessel contains HAP, except for material additions and sampling c. As specified in § 63.8005(i), on or before February 22, 2024, during the addition of dry material, route material containing metal HAP to a capture and control system that is maintained and operated according to the provisions of § 63.8005 i. Considering both capture and any combination of control (except a flare), reduce emissions of organic HAP with a vapor existing pressure ≥0.6 kPa by ≥75 percent by weight, and reduce emissions of organic HAP with a vapor pressure <0.6 kPa by ≥60 percent by weight. i. Reduce emissions of organic HAP with a vapor pressure ≥0.6 kPa by ≥75 percent by weight, and reduce emissions of organic HAP with a vapor pressure <0.6 kPa by ≥60 percent by weight, by venting emissions through a closed-vent system to any combination of control devices (except a flare); or

ii. Reduce emissions of total organic HAP by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare; or

iii. Reduce emissions of total organic HAP by venting emissions through a closed-vent system to a condenser that reduces the outlet gas temperature to:

<10 °C if the process vessel contains HAP with a partial pressure <0.6 kPa, or

<2 °C if the process vessel contains HAP with a partial pressure ≥0.6 kPa and <17.2 kPa, or

<−5 °C if the process vessel contains HAP with a partial pressure ≥17.2 kPa.

i. Reduce emissions of material containing metal HAP to 0.014 gr/dscf or less.

3. Portable and stationary process vessel at a new source a. Equip the vessel with a tightly fitting vented cover or lid that must be closed at all times when the vessel contains HAP, except for material additions and sampling b. As specified in § 63.8005(i), upon startup or February 22, 2023, whichever is later, during the addition of dry material, route material containing metal HAP to a capture and control system that is maintained and operated according to the provisions of § 63.8005 i. Reduce emissions of total organic HAP by ≥95 percent by weight by venting emissions through a closed-vent system to any combination of control devices (except a flare); or ii. Reduce emissions of total organic HAP by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare; or iii. Reduce emissions of total organic HAP by venting emissions through a closed-vent system to a condenser that reduces the outlet gas temperature to:

<−4 °C if the process vessel contains HAP with a partial pressure <0.7 kPa, or

<−20 °C if the process vessel contains HAP with a partial pressure ≥0.7 kPa and <17.2 kPa, or

<−30 °C if the process vessel contains HAP with a partial pressure ≥17.2 kPa.

i. Reduce emissions of material containing metal HAP to 0.0079 gr/dscf or less.

4. Halogenated vent stream from a process vessel subject to the requirements of item 2 or 3 of this table for which you use a combustion control device to control organic HAP emissions a. Use a halogen reduction device after the combustion control device; or b. Use a halogen reduction device before the combustion control device i. Reduce overall emissions of hydrogen halide and halogen HAP by ≥95 percent; or ii. Reduce overall emissions of hydrogen halide and halogen HAP to ≤0.45 kilogram per hour (kg/hr). Reduce the halogen atom mass emission rate to ≤0.45 kg/hr.

Collected 2026-08-27T02:26:04Z. Source file · JSON

Browse this collection