GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR Table 2 to Subpart AAAA of Part 60: Table 2 to Subpart AAAA of Part 60—Carbon Monoxide Emission Limits for New Small Municipal Waste Combustion Units

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
  5. Subpart AAAA—Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commenced After June 6, 2001

For the following municipal waste combustion units You must meet the following carbon monoxide limits a Using the following averaging times b

1. Fluidized-bed 100 parts per million by dry volume 4-hour.

2. Fluidized bed, mixed fuel, (wood/refuse-derived fuel) 200 parts per million by dry volume 24-hour. c

3. Mass burn rotary refractory 100 parts per million by dry volume 4-hour.

4. Mass burn rotary waterwall 100 parts per million by dry volume 24-hour.

5. Mass burn waterwall and refractory 100 parts per million by dry volume 4-hour.

6. Mixed fuel-fired (pulverized coal/refuse-derived fuel) 150 parts per million by dry volume 4-hour.

7. Modular starved-air and excess air 50 parts per million by dry volume 4-hour.

8. Spreader stoker, mixed fuel-fired (coal/refuse-derived fuel) 150 parts per million by dry volume 24-hour daily.

9. Stoker, refuse-derived fuel 150 parts per million by dry volume 24-hour daily.

a All limits (except for opacity) are measured at 7 percent oxygen. Compliance is determined by continuous emission monitoring systems.

b Block averages, arithmetic mean. See § 60.1465 for definitions.

c 24-hour block average, geometric mean. See § 60.1465 for definitions.