40 CFR Table 2 to Subpart MMMMM of Part 63: Table 2 to Subpart MMMMM of Part 63—Operating Limits for Existing, New, or Reconstructed Flame Lamination Affected Sources
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart MMMMM—National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations
As stated in § 63.8790(b), you must comply with the applicable operating limits in the following table:
For each . . . You must . . .
1. Scrubber a. Maintain the daily average scrubber inlet liquid flow rate above the minimum value established during the performance test.
b. Maintain the daily average scrubber effluent pH within the operating range value established during the performance test.
c. If you use a venturi scrubber, maintain the daily average pressure drop across the venturi within the operating range value established during the performance test.
2. Other type of control device to which flame lamination emissions are ducted Maintain your operating parameter(s) within the ranges established during the performance test and according to your monitoring plan.