40 CFR Table 2 to Subpart OOOOb of Part 60: Table 2 to Subpart OOOOb of Part 60—Alternative Technology Periodic Screening Frequency at Well Sites and Centralized Production Facilities Subject to AVO Inspections and/or Semiannual OGI or EPA Method 21 Monitoring
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
- Subpart OOOOb—Standards of Performance for Crude Oil and Natural Gas Facilities for Which Construction, Modification or Reconstruction Commenced After December 6, 2022
Minimum screening frequency Minimum detection threshold of screening technology * (kg/hr)
Semiannual ≤1
Triannual ≤2
Triannual + Annual OGI ≤10
Quarterly ≤5
Quarterly + Annual OGI ≤15
Bimonthly ≤15
* Based on a probability of detection of 90%