40 CFR Table 3 to Subpart RRRRR of Part 63: Table 3 to Subpart RRRRR of Part 63—Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart RRRRR—National Emission Standards for Hazardous Air Pollutants: Taconite Iron Ore Processing
Table 3 to Subpart RRRRR of Part 63—Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces
[As required in § 63.9590(a), you must comply with each applicable hydrogen chloride and hydrogen fluoride emission limit in the following table:]
For . . . You must meet the following emission limits . . .
1. Indurating furnaces constructed or reconstructed before May 15, 2023 Hydrogen chloride emissions must not exceed 4.6 × 10−2 lb/Long Ton of taconite pellets produced.
Hydrogen fluoride emissions must not exceed 1.2 × 10−2 lb/Long Ton of taconite pellets produced.
2. Indurating furnaces constructed or reconstructed on or after May 15, 2023 Hydrogen chloride emissions must not exceed 4.4 × 10−4 lb/Long Ton of taconite pellets produced
Hydrogen fluoride emissions must not exceed 3.3 × 10−4 lb/Long Ton of taconite pellets produced.
Collected 2026-08-27T02:26:04Z. Source file · JSON