GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR Table 3 to Subpart RRRRR of Part 63: Table 3 to Subpart RRRRR of Part 63—Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
  5. Subpart RRRRR—National Emission Standards for Hazardous Air Pollutants: Taconite Iron Ore Processing

Table 3 to Subpart RRRRR of Part 63—Hydrogen Chloride and Hydrogen Fluoride Emission Limits for Indurating Furnaces

[As required in § 63.9590(a), you must comply with each applicable hydrogen chloride and hydrogen fluoride emission limit in the following table:]

For . . . You must meet the following emission limits . . .

1. Indurating furnaces constructed or reconstructed before May 15, 2023 Hydrogen chloride emissions must not exceed 4.6 × 10−2 lb/Long Ton of taconite pellets produced.

Hydrogen fluoride emissions must not exceed 1.2 × 10−2 lb/Long Ton of taconite pellets produced.

2. Indurating furnaces constructed or reconstructed on or after May 15, 2023 Hydrogen chloride emissions must not exceed 4.4 × 10−4 lb/Long Ton of taconite pellets produced

Hydrogen fluoride emissions must not exceed 3.3 × 10−4 lb/Long Ton of taconite pellets produced.