40 CFR Table 4 to Subpart OOO of Part 63: Table 4 to Subpart OOO of Part 63—Operating Parameter Levels
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart OOO—National Emission Standards for Hazardous Air Pollutant Emissions: Manufacture of Amino/Phenolic Resins
Device Parameters to be monitored Established operating parameter(s)
Scrubber pH of scrubber effluent; and scrubber liquid and gas flow rates Minimum pH; and minimum liquid/gas ratio
Absorber Exit temperature of the absorbing liquid; and exit specific gravity of the absorbing liquid Maximum temperature; and maximum specific gravity
Condenser Exit temperature Maximum temperature
Carbon absorber Total regeneration steam or nitrogen flow, or pressure (gauge or absolute) a during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum flow or pressure; and maximum temperature
Thermal incinerator Firebox temperature Minimum temperature
Catalytic incinerator Temperature upstream and downstream of the catalyst bed Minimum upstream temperature; and minimum temperature difference across the catalyst bed
Boiler or process heater Firebox temperature Minimum temperature
Other devices (or as an alternate to the requirements previously presented in this table) b Organic HAP concentration level or reading at outlet of device Maximum organic HAP concentration or reading
a 25 to 50 mm (absolute) is a common pressure level obtained by pressure swing absorbers.
b Concentration is measured instead of an operating parameter.
Collected 2026-08-27T02:26:04Z. Source file · JSON