40 CFR Table 5 to Subpart JJJ of Part 63: Table 5 to Subpart JJJ of Part 63—Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart JJJ—National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins
Thermoplastic Chemical a Vessel capacity (cubic meters) Vapor pressure b (kilopascals)
ASA/AMSAN c Styrene/ acrylonitrile mixture ≥3.78 ≥0.47
Acrylonitrile ≥75.7 ≥1.62
SAN, continuous d All chemicals ≥2,271 ≥0.5 and <0.7
<151 ≥10
≥151 ≥0.7
Nitrile c Acrylonitrile ≥13.25 ≥1.8
Polystyrene, continuous processes All chemicals ≥19.6 and <45.4 ≥7.48
≥45.4 and <109.8 ≥0.61
≥109.8 ≥0.53
ABS, continuous mass Styrene ≥45.43 ≥0.078
All other chemicals ≥38 and <45.43 ≥13.1
≥45.43 ≥0.53
a Vessel capacity and vapor pressure criteria are specific to the listed chemical, to “all chemicals,” or to “all other chemicals,” as indicated.
b Maximum true vapor pressure of total organic HAP at storage temperature.
c The applicability criteria in Table 4 of this subpart shall be used for chemicals not specifically listed in this table (i.e., Table 5).
d The control level for the first two sets of applicability criteria are specified in 63.1314 as 90% and 98%, respectively. The control level for the third set of applicability criteria is the HON control level of 95%.