40 CFR Table 8 to Subpart ZZZZ of Part 63: Table 8 to Subpart ZZZZ of Part 63—Applicability of General Provisions to Subpart ZZZZ
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart ZZZZ—National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines
As stated in § 63.6665, you must comply with the following applicable general provisions.
General provisions citation Subject of citation Applies to subpart Explanation
§ 63.1 General applicability of the General Provisions Yes
§ 63.2 Definitions Yes Additional terms defined in § 63.6675.
§ 63.3 Units and abbreviations Yes
§ 63.4 Prohibited activities and circumvention Yes
§ 63.5 Construction and reconstruction Yes
§ 63.6(a) Applicability Yes
§ 63.6(b)(1)-(4) Compliance dates for new and reconstructed sources Yes
§ 63.6(b)(5) Notification Yes
§ 63.6(b)(6) [Reserved]
§ 63.6(b)(7) Compliance dates for new and reconstructed area sources that become major sources Yes
§ 63.6(c)(1)-(2) Compliance dates for existing sources Yes
§ 63.6(c)(3)-(4) [Reserved]
§ 63.6(c)(5) Compliance dates for existing area sources that become major sources Yes
§ 63.6(d) [Reserved]
§ 63.6(e) Operation and maintenance No
§ 63.6(f)(1) Applicability of standards No
§ 63.6(f)(2) Methods for determining compliance Yes
§ 63.6(f)(3) Finding of compliance Yes
§ 63.6(g)(1)-(3) Use of alternate standard Yes
§ 63.6(h) Opacity and visible emission standards No Subpart ZZZZ does not contain opacity or visible emission standards.
§ 63.6(i) Compliance extension procedures and criteria Yes
§ 63.6(j) Presidential compliance exemption Yes
§ 63.7(a)(1)-(2) Performance test dates Yes Subpart ZZZZ contains performance test dates at §§ 63.6610, 63.6611, and 63.6612.
§ 63.7(a)(3) CAA section 114 authority Yes
§ 63.7(b)(1) Notification of performance test Yes Except that § 63.7(b)(1) only applies as specified in § 63.6645.
§ 63.7(b)(2) Notification of rescheduling Yes Except that § 63.7(b)(2) only applies as specified in § 63.6645.
§ 63.7(c) Quality assurance/test plan Yes Except that § 63.7(c) only applies as specified in § 63.6645.
§ 63.7(d) Testing facilities Yes
§ 63.7(e)(1) Conditions for conducting performance tests No Subpart ZZZZ specifies conditions for conducting performance tests at § 63.6620.
§ 63.7(e)(2) Conduct of performance tests and reduction of data Yes Subpart ZZZZ specifies test methods at § 63.6620.
§ 63.7(e)(3) Test run duration Yes
§ 63.7(e)(4) Administrator may require other testing under section 114 of the CAA Yes
§ 63.7(f) Alternative test method provisions Yes
§ 63.7(g) Performance test data analysis, recordkeeping, and reporting Yes
§ 63.7(h) Waiver of tests Yes
§ 63.8(a)(1) Applicability of monitoring requirements Yes Subpart ZZZZ contains specific requirements for monitoring at § 63.6625.
§ 63.8(a)(2) Performance specifications Yes
§ 63.8(a)(3) [Reserved]
§ 63.8(a)(4) Monitoring for control devices No
§ 63.8(b)(1) Monitoring Yes
§ 63.8(b)(2)-(3) Multiple effluents and multiple monitoring systems Yes
§ 63.8(c)(1) Monitoring system operation and maintenance Yes
§ 63.8(c)(1)(i) Routine and predictable SSM No
§ 63.8(c)(1)(ii) SSM not in Startup Shutdown Malfunction Plan Yes
§ 63.8(c)(1)(iii) Compliance with operation and maintenance requirements No
§ 63.8(c)(2)-(3) Monitoring system installation Yes
§ 63.8(c)(4) Continuous monitoring system (CMS) requirements Yes Except that subpart ZZZZ does not require Continuous Opacity Monitoring System (COMS).
§ 63.8(c)(5) COMS minimum procedures No Subpart ZZZZ does not require COMS.
§ 63.8(c)(6)-(8) CMS requirements Yes Except that subpart ZZZZ does not require COMS.
§ 63.8(d) CMS quality control Yes
§ 63.8(e) CMS performance evaluation Yes Except for § 63.8(e)(5)(ii), which applies to COMS.
Except that § 63.8(e) only applies as specified in § 63.6645.
§ 63.8(f)(1)-(5) Alternative monitoring method Yes Except that § 63.8(f)(4) only applies as specified in § 63.6645.
§ 63.8(f)(6) Alternative to relative accuracy test Yes Except that § 63.8(f)(6) only applies as specified in § 63.6645.
§ 63.8(g) Data reduction Yes Except that provisions for COMS are not applicable. Averaging periods for demonstrating compliance are specified at §§ 63.6635 and 63.6640.
§ 63.9(a) Applicability and State delegation of notification requirements Yes
§ 63.9(b)(1)-(5) Initial notifications Yes Except that § 63.9(b)(3) is reserved.
Except that § 63.9(b) only applies as specified in § 63.6645.
§ 63.9(c) Request for compliance extension Yes Except that § 63.9(c) only applies as specified in § 63.6645.
§ 63.9(d) Notification of special compliance requirements for new sources Yes Except that § 63.9(d) only applies as specified in § 63.6645.
§ 63.9(e) Notification of performance test Yes Except that § 63.9(e) only applies as specified in § 63.6645.
§ 63.9(f) Notification of visible emission (VE)/opacity test No Subpart ZZZZ does not contain opacity or VE standards.
§ 63.9(g)(1) Notification of performance evaluation Yes Except that § 63.9(g) only applies as specified in § 63.6645.
§ 63.9(g)(2) Notification of use of COMS data No Subpart ZZZZ does not contain opacity or VE standards.
§ 63.9(g)(3) Notification that criterion for alternative to RATA is exceeded Yes If alternative is in use. Except that § 63.9(g) only applies as specified in § 63.6645.
§ 63.9(h)(1)-(6) Notification of compliance status Yes Except that notifications for sources using a CEMS are due 30 days after completion of performance evaluations. § 63.9(h)(4) is reserved.
Except that § 63.9(h) only applies as specified in § 63.6645.
§ 63.9(i) Adjustment of submittal deadlines Yes
§ 63.9(j) Change in previous information Yes
§ 63.9(k) Electronic reporting procedures Yes Only as specified in §§ 63.9(j), 63.6620, 63.6625, 63.6645, and 63.6650.
§ 63.10(a) Administrative provisions for recordkeeping/reporting Yes
§ 63.10(b)(1) Record retention Yes Except that the most recent 2 years of data do not have to be retained on site.
§ 63.10(b)(2)(i)-(v) Records related to SSM No
§ 63.10(b)(2)(vi)-(xi) Records Yes
§ 63.10(b)(2)(xii) Record when under waiver Yes
§ 63.10(b)(2)(xiii) Records when using alternative to RATA Yes For CO standard if using RATA alternative.
§ 63.10(b)(2)(xiv) Records of supporting documentation Yes
§ 63.10(b)(3) Records of applicability determination Yes
§ 63.10(c) Additional records for sources using CEMS Yes Except that § 63.10(c)(2)-(4) and (9) are reserved.
§ 63.10(d)(1) General reporting requirements Yes
§ 63.10(d)(2) Report of performance test results Yes
§ 63.10(d)(3) Reporting opacity or VE observations No Subpart ZZZZ does not contain opacity or VE standards.
§ 63.10(d)(4) Progress reports Yes
§ 63.10(d)(5) Startup, shutdown, and malfunction reports No
§ 63.10(e)(1) and (2)(i) Additional CMS Reports Yes
§ 63.10(e)(2)(ii) COMS-related report No Subpart ZZZZ does not require COMS.
§ 63.10(e)(3) Excess emission and parameter exceedances reports No Excess emissions and exceedance reporting is specified in § 63.6650.
§ 63.10(e)(4) Reporting COMS data No Subpart ZZZZ does not require COMS.
§ 63.10(f) Waiver for recordkeeping/reporting Yes
§ 63.11 Flares No
§ 63.12 State authority and delegations Yes
§ 63.13 Addresses Yes
§ 63.14 Incorporation by reference Yes
§ 63.15 Availability of information Yes
Collected 2026-08-27T02:26:04Z. Source file · JSON