GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR Table C-1 to Subpart C of Part 53: Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER C—AIR PROGRAMS
  4. PART 53—AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS
  5. Subpart C—Procedures for Determining Comparability Between Candidate Methods and Reference Methods

Pollutant Concentration range, parts per million (ppm) Simultaneous measurements required Maximum discrepancy specification, parts per million

1-hour 24-hour

First set Second set First set Second set

Ozone Low 0.06 to 0.10 5 6 0.02

Med. 0.15 to 0.25 5 6 0.03

High 0.35 to 0.46 4 6 0.04

Total 14 18

Carbon monoxide Low 7 to 11 5 6 1.5

Med. 20 to 30 5 6 2.0

High 25 to 45 4 6 3.0

Total 14 18

Sulfur dioxide Low 0.02 to 0.05 5 6 3 3 0.02

Med. 0.10 to 0.15 5 6 2 3 0.03

High 0.30 to 0.50 4 6 2 2 0.04

Total 14 18 7 8

Nitrogen dioxide Low 0.02 to 0.08 3 3 0.02

Med. 0.10 to 0.20 2 2 0.02

High 0.25 2 2 0.03

Total 7 8