GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

42 CFR 84.122: Breathing resistance test; minimum requirements.

Read at publisher ↗
Where this section sits in the code
  1. Title 42—Public Health
  2. CHAPTER I—PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES
  3. SUBCHAPTER G—OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES
  4. PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
  5. Subpart I—Gas Masks

(a) Resistance to airflow will be measured in the facepiece or mouthpiece of a gas mask mounted on a breathing machine both before and after each test conducted in accordance with §§ 84.124, 84.125, and 84.126, with air flowing at a continuous rate of 85 liters per minute.

(b) The maximum allowable resistance requirements for gas masks are as follows:

Maximum Resistance

[mm. water-column height]

Type of gas mask Inhalation Exhalation

Initial Final 1

Front-mounted or back-mounted (without particulate filter) 60 75 20

Front-mounted or back-mounted (with approved particulate filter) 70 85 20

Chin-style (without particulate filter) 40 55 20

Chin-style (with approved particulate filter) 65 80 20

Escape (without particulate filter) 60 75 20

Escape (with approved particulate filter) 70 85 20

1 Measured at end of the service life specified in Tables 5, 6, and 7 of this subpart.