Table 5—Canister Bench Tests and Requirements for Front-Mounted and Back-Mounted Gas Mask Canisters
[42 CFR part 84, subpart I]
Canister type Test condition Test atmosphere Number of tests Maximum allowable penetratin (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gas As received SO2 20,000 64 3 5 12
Equilibrated Cl2 20,000 64 3 5 12
SO2 20,000 32 4 5 12
Cl2 20,000 32 4 5 12
Organic vapor As received CCl4 20,000 64 3 5 12
Equilibrated CCl4 20,000 32 4 5 12
Ammonia As received NH3 30,000 64 3 50 12
Equilibrated NH3 30,000 32 4 50 12
Carbon monoxide As received CO 20,000 4 64 2 (3) 60
Equilibrated CO 5,000 2 32 3 (3) 60
CO 3,000 2 32 3 (3) 60
Combination of 2 or 3 of above types 5
Combination of all above types 6
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.
5 Test conditions and requirements will be applicable as shown in this table.
6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.
Table 6—Canister Bench Tests and Requirements for Chin-Style Gas Mask Canisters
[42 CFR part 84, subpart I]
Canister type Test condition Test atmosphere Number of tests Maximum allowable penetration (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gas As received Equilibrated SO2 50,000 64 3 5 12
Cl2 5,000 64 3 5 12
SO2 5,000 32 4 5 12
Cl2 5,000 32 4 5 12
Organic vapor As received Equilibrated CCl4 5,000 64 3 5 12
CCl4 5,000 32 4 5 12
Ammonia As received Equilibrated NH3 5,000 64 3 50 12
As received Equilibrated NH3 5,000 32 4 50 12
Carbon monoxide As received CO 20,000 2 64 2 (3) 60
CO 5,000 4 32 3 (3) 60
CO 3,000 2 32 3 (3) 60
Combination of 2 or 3 of above types 5
Combination of all above types 6
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.
5 Test conditions and requirements will be applicable as shown in this table.
6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.
Table 7—Canister Bench Tests and Requirements for Escape Gas Mask Canisters
[42 CFR part 84, subpart I]
Canister type Test condition Test atmosphere Number of tests Maximum allowable penetration (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gas As received SO2 5,000 64 3 5 12
Equilibrated Cl2 5,000 64 3 5 12
SO2 5,000 32 4 5 12
Cl2 5,000 32 4 5 12
Organic vapor As received CCl4 5,000 64 3 5 12
Equilibrated CCl4 5,000 32 4 5 12
Ammonia As received NH3 5,000 64 3 50 12
Equilibrated NH3 5,000 32 4 50 12
Carbon monoxide As received CO 10,000 2 32 2 (3) 4 60
CO 5,000 5 32 3 (3) 60
CO 3,000 2 32 3 (3) 60
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere will be 25 ±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 If effluent temperature exceeds 100 °C during this test, the escape gas mask shall be equipped with an effective heat exchanger.
5 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.
Collected 2026-08-27T02:26:11Z. Source file · JSON