46 CFR 112.43-15: -15 Emergency lighting feeders.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER J—ELECTRICAL ENGINEERING
- PART 112—EMERGENCY LIGHTING AND POWER SYSTEMS
- Subpart 112.43—Emergency Lighting Systems
For a vessel with fire bulkheads forming fire zones, at least one emergency lighting feeder must supply only the emergency lights between two adjacent main vertical fire zone bulkheads. The emergency lighting feeder must be separated as widely as practicable from any general lighting feeder supplying the same space.
Collected 2026-08-27T02:26:22Z. Source file · JSON