46 CFR 113.25-11: -11 Contact makers.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER J—ELECTRICAL ENGINEERING
- PART 113—COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT
- Subpart 113.25—General Emergency Alarm Systems
Each contact maker must—
(a) Have normally open contacts and be constructed in accordance with Type 4 or 4X of NEMA 250 or IP 56 of IEC 60529:2013 (both incorporated by reference; see § 110.10-1 of this subpart) requirements;
(b) Have a switch handle that can be maintained in the “on” position;
(c) Have the “off” and “on” positions of the operating handle permanently marked; and
(d) Have an inductive load rating not less than the connected load or, on large vessels, have auxiliary devices to interrupt the load current.