46 CFR 120.210: Protection from wet and corrosive environments.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER K—SMALL PASSENGER VESSELS CARRYING MORE THAN 150 PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS
- PART 120—ELECTRICAL INSTALLATION
- Subpart B—General Requirements
(a) Electrical equipment used in the following locations must be dripproof:
(1) A machinery space;
(2) A location normally exposed to splashing, water washdown, or other wet conditions within a galley, a laundry, or a public washroom or toilet room that has a bath or shower; or
(3) Another space with a similar moisture level.
(b) Electrical equipment exposed to the weather must be watertight.
(c) Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion-resistant.