GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

46 CFR 132.200: General.

Read at publisher ↗
Where this section sits in the code
  1. Title 46—Shipping
  2. CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
  3. SUBCHAPTER L—OFFSHORE SUPPLY VESSELS
  4. PART 132—FIRE-PROTECTION EQUIPMENT
  5. Subpart B—Portable and Semiportable Fire Extinguishers

(a) Except as provided by paragraph (b) of this section, each OSV must be equipped with portable and semiportable fire extinguishers that comply with this subpart.

(b) Each OSV of at least 6,000 GT ITC (500 GRT if GT ITC is not assigned) must, in addition to complying with the requirements necessary to satisfy § 125.105(a) and (b) of this subchapter, be equipped with the number and type of portable and semiportable fire extinguishers listed in § 34.50 of this chapter.

Collected 2026-08-27T02:26:22Z. Source file · JSON

Browse this collection