46 CFR 153.350: Location of B/3 vent discharges.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES
- PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS
- Subpart B—Design and Equipment
Except as prescribed in § 153.353, a
B/3 venting system must discharge:
(a) At the highest of the following points:
(1) 6m (approx. 19.7 ft) above the weatherdeck.
(2) B/3 above the weatherdeck.
(3) 6m (approx. 19.7 ft) above a walkway, if the walkway is within a 6m (approx. 19.7 ft) horizontal radius from the vent discharge.
(b) At least 15m (approx. 49.2 ft) from air intakes for, or openings into, accommodation and service spaces.