46 CFR 153.361: Arrangements for removal of valves from venting systems having multiple relief valves.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES
- PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS
- Subpart B—Design and Equipment
A venting system having multiple relief valves may be arranged to allow the removal of a valve (for repair, as an example) provided the venting system:
(a) Has valves that are interlocked, so that the removal of a valve does not reduce the venting system relieving capacity below the minimum relieving capacity required by § 153.358; and
(b) Is arranged so that cargo vapor will not escape through the opening left after a valve has been removed.