46 CFR 153.406: Standards for containment systems having required restricted gauges.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES
- PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS
- Subpart B—Design and Equipment
When Table 1 requires a cargo's containment system to have a restricted gauge, the containment system must have:
(a) A closed gauging system; or
(b) A system that has:
(1) A restricted gauge (e.g., a sounding tube) with an orifice diameter not exceeding 20 cm (approx. 7.8 in.);
(2) A permanently attached gauge cover that is vapor tight when in place; and
(3) A venting system that has either:
(i) Lock open PV valves; or
(ii) Valved bypasses around the PV valves.