46 CFR 169.315: Ventilation (other than machinery spaces).
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER R—NAUTICAL SCHOOLS
- PART 169—SAILING SCHOOL VESSELS
- Subpart 169.300—Construction and Arrangement
(a) All enclosed spaces within the vessel must be properly ventilated in a manner suitable for the purpose of the space.
(b) A means must be provided to close off all vents and ventilators.
(c) Living spaces must be ventilated by a mechanical system unless it can be shown that a natural system will provide adequate ventilation in all ordinary weather conditions. Provided that paragraph (a) of this section is satisfied, a vessel having only a natural ventilation system must satisfy the following: V/A≥1.4 where V is the total area of the vents in square inches and A is the product in square feet of the vessel's design waterline length times its maximum beam.