46 CFR 182.530: Bilge high level alarms.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER T—SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS)
- PART 182—MACHINERY INSTALLATION
- Subpart E—Bilge and Ballast Systems
(a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.
(b) Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.
(c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.