GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

46 CFR 32.56-50: -50 Combustible veneers—T/ALL.

Read at publisher ↗
Where this section sits in the code
  1. Title 46—Shipping
  2. CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
  3. SUBCHAPTER D—TANK VESSELS
  4. PART 32—SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS
  5. Subpart 32.56—Structural Fire Protection for Tank Ships With a Keel Laying Date On or After January 1, 1975

(a) Except as provided in paragraph (b) of this section combustible veneers on bulkheads, linings, and ceilings within accommodation, service, or control spaces must be 2 millimeters (.079 inches) or less in thickness.

(b) Veneers on bulkheads, linings, and ceilings in concealed spaces, corridors, stairway enclosures, or control spaces must be an approved interior finish material or a reasonable number of coats of paint.

Collected 2026-08-27T02:26:22Z. Source file · JSON

Browse this collection