46 CFR 53.05-1: -1 Safety valve requirements for steam boilers (modifies HG-400 and HG-401).
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER F—MARINE ENGINEERING
- PART 53—HEATING BOILERS
- Subpart 53.05—Pressure Relieving Devices (Article 4)
(a) The pressure relief valve requirements and the safety valve requirements for steam boilers must be as indicated in HG-400 and HG-401 of Section IV of the ASME BPVC (incorporated by reference; see § 53.01-1) except as noted otherwise in this section.
(b) Each steam boiler must have at least one safety valve.