GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

46 CFR 56.50-20: -20 Pressure relief piping.

Read at publisher ↗
Where this section sits in the code
  1. Title 46—Shipping
  2. CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
  3. SUBCHAPTER F—MARINE ENGINEERING
  4. PART 56—PIPING SYSTEMS AND APPURTENANCES
  5. Subpart 56.50—Design Requirements Pertaining to Specific Systems

(a) General. There must be no intervening stop valves between the pressure vessel or piping system being protected and its protective device or devices, except as authorized by the Marine Safety Center.

(b) Discharge lines. (Reproduces 122.6.2(d).) Discharge lines from pressure-relieving safety devices must be designed to facilitate drainage.

(c) Stop valves. Stop valves between the safety or relief valve and the point of discharge are not permitted, except as specifically approved by the Marine Safety Center.

(d) Reference. See also § 56.07-10(a) and (b) for specific requirements.

Collected 2026-08-27T02:26:22Z. Source file · JSON