46 CFR 62.25-30: -30 Environmental design standards.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER F—MARINE ENGINEERING
- PART 62—VITAL SYSTEM AUTOMATION
- Subpart 62.25—General Requirements for All Automated Vital Systems
(a) All automation must be suitable for the marine environment and must be designed and constructed to operate indefinitely under the following conditions:
(1) Ship motion and vibration described in Table 1 of section 4-9-9 of the ABS Marine Vessel Rules (incorporated by reference; see § 62.05-1); note that inclination requirements for fire and flooding safety systems are described in § 112.05-5(c) of this chapter.
(2) Ambient air temperatures described in Table 1 of part 4-9-9/3 of the ABS Marine Vessel Rules.
(3) Electrical voltage and frequency tolerances described in Table 1 of part 4-9-9 of the ABS Marine Vessel Rules.
(4) Relative humidity of 0 to 95% at 45 °C.
(5) Hydraulic and pneumatic pressure variations described in Table 1 of part 4-9-9 of the ABS Marine Vessel Rules.
Note 1 to paragraph (a):
Considerations should include normal dynamic conditions that might exceed these values, such as switching, valve closure, power supply transfer, starting, and shutdown.
(b) Low voltage electronics must be designed with due consideration for static discharge, electromagnetic interference, voltage transients, fungal growth, and contact corrosion.
Collected 2026-08-27T02:26:22Z. Source file · JSON