49 CFR 192.189: Vaults: Drainage and waterproofing.
Where this section sits in the code
- Title 49—Transportation
- Subtitle B—Other Regulations Relating to Transportation
- CHAPTER I—PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
- SUBCHAPTER D—PIPELINE SAFETY
- PART 192—TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS
- Subpart D—Design of Pipeline Components
(a) Each vault must be designed so as to minimize the entrance of water.
(b) A vault containing gas piping may not be connected by means of a drain connection to any other underground structure.
(c) Electrical equipment in vaults must conform to the applicable requirements of Class 1, Group D, of the National Electrical Code, NFPA-70 (incorporated by reference, see § 192.7).
Collected 2026-08-27T02:26:34Z. Source file · JSON