GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

49 CFR 213.137: Frogs.

Read at publisher ↗
Where this section sits in the code
  1. Title 49—Transportation
  2. Subtitle B—Other Regulations Relating to Transportation
  3. CHAPTER II—FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
  4. PART 213—TRACK SAFETY STANDARDS
  5. Subpart D—Track Structure

(a) Except as provided in paragraph (e) of this section, the flangeway depth measured from a plane across the wheel-bearing area of a frog on Class 1 track shall not be less than 1 3/8 inches, or less than 1 1/2 inches on Classes 2 through 5 track.

(b) If a frog point is chipped, broken, or worn more than five-eighths inch down and 6 inches back, operating speed over the frog shall not be more than 10 m.p.h.

(c) If the tread portion of a frog casting is worn down more than three-eighths inch below the original contour, operating speed over that frog shall not be more than 10 m.p.h.

(d) Where frogs are designed as flange-bearing, flangeway depth may be less than that shown for Class 1 if operated at Class 1 speeds.

(e) The flange depth requirements in paragraph (a) do not apply to a frog designed as a flange-bearing frog (FBF) used in a crossing diamond in Classes 2 through 5 track, provided that the crossing angle is greater than 20 degrees unless movable guard rails are used.

Collected 2026-08-27T02:26:34Z. Source file · JSON