GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

49 CFR 230.59: Fusible plugs.

Read at publisher ↗
Where this section sits in the code
  1. Title 49—Transportation
  2. Subtitle B—Other Regulations Relating to Transportation
  3. CHAPTER II—FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
  4. PART 230—STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS
  5. Subpart B—Boilers and Appurtenances

If boilers are equipped with fusible plugs, the plugs shall be removed and cleaned of scale each time the boiler is washed but not less frequently than during every 31 service day inspection. Their removal shall be noted on the FRA Form No. 1 or FRA Form No. 3. (See appendix B of this part.)

Collected 2026-08-27T02:26:34Z. Source file · JSON