GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

49 CFR 234.243: Wire on pole line and aerial cable.

Read at publisher ↗
Where this section sits in the code
  1. Title 49—Transportation
  2. Subtitle B—Other Regulations Relating to Transportation
  3. CHAPTER II—FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
  4. PART 234—GRADE CROSSING SAFETY
  5. Subpart D—Maintenance, Inspection, and Testing

Wire on a pole line shall be securely attached to an insulator that is properly fastened to a cross arm or bracket supported by a pole or other support. Wire shall not interfere with, or be interfered with by, other wires on the pole line. Aerial cable shall be supported by messenger wire. An open-wire transmission line operating at voltage of 750 volts or more shall be placed not less than 4 feet above the nearest cross arm carrying active warning system circuits.

Collected 2026-08-27T02:26:34Z. Source file · JSON