10 CFR 36.37: Power failures.
Where this section sits in the code
- Title 10—Energy
- CHAPTER I—NUCLEAR REGULATORY COMMISSION
- PART 36—LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS
- Subpart C—Design and Performance Requirements for Irradiators
(a) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must automatically return to the shielded position.
(b) The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.
(c) During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.