GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

30 CFR 77.807-2: -2 Booms and masts; minimum distance from high-voltage lines.

Read at publisher ↗
Where this section sits in the code
  1. Title 30—Mineral Resources
  2. CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
  3. SUBCHAPTER O—COAL MINE SAFETY AND HEALTH
  4. PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES
  5. Subpart I—Surface High-Voltage Distribution

The booms and masts of equipment operated on the surface of any coal mine shall not be operated within 10 feet of an energized overhead powerline. Where the voltage of overhead powerlines is 69,000 volts, or more, the minimum distance from the boom or mast shall be as follows:

Nominal power line voltage (in 1,000 volts) Minimum distance (feet)

69 to 114 12

115 to 229 15

230 to 344 20

345 to 499 25

500 or more 35

Collected 2026-08-27T02:25:24Z. Source file · JSON