GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR 420.102: Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart J—Cold Forming Subcategory

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

(a) Cold rolling mills—(1) Recirculation—single stand.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.00125 0.000626

O&G 0.000522 0.000209

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

Naphthalene 0.0000021

Tetrachloroethylene 0.0000031

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(2) Recirculation—multiple stands.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.00626 0.00313

O&G 0.00261 0.00104

Chromium 1 0.000104 0.0000418

Lead 0.0000469 0.0000156

Nickel 1 0.0000939 0.0000313

Zinc 0.0000313 0.0000104

Naphthalene 0.0000104

Tetrachloroethylene 0.0000156

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(3) Combination.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.0751 0.0376

O&G 0.0313 0.0125

Chromium 1 0.00125 0.000501

Lead 0.000563 0.000188

Nickel 1 0.00113 0.000376

Zinc 0.000376 0.000125

Naphthalene 0.000125

Tetrachloroethylene 0.000188

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are cotreated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(4) Direct application—single stand.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.0225 0.0113

O&G 0.00939 0.00376

Chromium 1 0.000376 0.000150

Lead 0.000169 0.0000563

Nickel 1 0.000338 0.000113

Zinc 0.000113 0.0000376

Naphthalene 0.0000376

Tetrachloroethylene 0.0000563

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(5) Direct application—multiple stands.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.100 0.0501

O&G 0.0417 0.0167

Chromium 1 0.00167 0.000668

Lead 0.000751 0.000250

Nickel 1 0.00150 0.000501

Zinc 0.000501 0.000167

Naphthalene 0.000167

Tetrachloroethylene 0.000250

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(b) Cold worked pipe and tube—(1) Using water.

Subpart J

Pollutant of pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.00125 0.000626

O&G 0.000522 0.000209

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

(2) Using oil solutions.

Subpart J

Pollutant or pollutant property BPT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

TSS 0.00125 0.000626

O&G 0.000522 0.000209

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

Naphthalene 0.0000021

Tetrachloroethylene 0.0000031

pH (2) (2)

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

2 Within the range of 6.0 to 9.0.

Collected 2026-08-27T02:26:04Z. Source file · JSON

Browse this collection