GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

40 CFR 420.103: Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Read at publisher ↗
Where this section sits in the code
  1. Title 40—Protection of Environment
  2. CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
  3. SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
  4. PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY
  5. Subpart J—Cold Forming Subcategory

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

(a) Cold rolling mills—(1) Recirculation—single stand.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

Naphthalene 0.0000021

Tetrachloroethylene 0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Recirculation—multiple stands.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.000104 0.0000418

Lead 0.0000469 0.0000156

Nickel 1 0.0000939 0.0000313

Zinc 0.0000313 0.0000104

Naphthalene 0.0000104

Tetrachloroethylene 0.0000156

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(3) Combination.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.00125 0.000501

Lead 0.000563 0.000188

Nickel 1 0.00113 0.000376

Zinc 0.000376 0.000125

Naphthalene 0.000125

Tetrachloroethylene 0.000188

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are cotreated with descaling or combination acid pickling wastewaters.

(4) Direct application—single stand.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.000376 0.000150

Lead 0.000169 0.0000563

Nickel 1 0.000338 0.000113

Zinc 0.000113 0.0000376

Naphthalene 0.0000376

Tetrachloroethylene 0.0000563

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(5) Direct application—multiple stands.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.00167 0.000668

Lead 0.000751 0.000250

Nickel 1 0.00150 0.000501

Zinc 0.000501 0.000167

Naphthalene 0.000167

Tetrachloroethylene 0.000250

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(b) Cold worked pipe and tube—(1) Using water.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Using oil solutions.

Subpart J

Pollutant or pollutant property BAT effluent limitations

Maximum for any 1 day Average of daily values for 30 consecutive days

Kg/kkg (pounds per 1,000 lb) of product

Chromium 1 0.0000209 0.0000084

Lead 0.0000094 0.0000031

Nickel 1 0.0000188 0.0000063

Zinc 0.0000063 0.0000021

Naphthalene 0.0000021

Tetrachloroethylene 0.0000031

1 The limitations for chromium and nickel shall be applicable in lieu of those for lead and zinc when cold forming wastewaters are treated with descaling or combination acid pickling wastewaters.