40 CFR 445.11: Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS
- PART 445—LANDFILLS POINT SOURCE CATEGORY
- Subpart A—RCRA Subtitle C Hazardous Waste Landfill
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:
Effluent Limitations
Regulated parameter Maximum daily 1 Maximum monthly avg. 1
BOD5 220 56
TSS 88 27
Ammonia (as N) 10 4.9
α-Terpineol 0.042 0.019
Aniline 0.024 0.015
Benzoic acid 0.119 0.073
Naphthalene 0.059 0.022
p-Cresol 0.024 0.015
Phenol 0.048 0.029
Pyridine 0.072 0.025
Arsenic 1.1 0.54
Chromium 1.1 0.46
Zinc 0.535 0.296
pH (2) (2)
1 Milligrams per liter (mg/L, ppm).
2 Within the range 6 to 9.
Collected 2026-08-27T02:26:04Z. Source file · JSON