40 CFR 60.4360: How do I determine the total sulfur content of the turbine's combustion fuel?
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES
- Subpart KKKK—Standards of Performance for Stationary Combustion Turbines
You must monitor the total sulfur content of the fuel being fired in the turbine, except as provided in § 60.4365. The sulfur content of the fuel must be determined using total sulfur methods described in § 60.4415. Alternatively, if the total sulfur content of the gaseous fuel during the most recent performance test was less than half the applicable limit, ASTM D4084-05, D4810-88 (Reapproved 1999), D5504-01, or D6228-98 (Reapproved 2003), or Gas Processors Association Standard 2377-86 (all of which are incorporated by reference, see § 60.17), which measure the major sulfur compounds, may be used.
Collected 2026-08-27T02:26:04Z. Source file · JSON