40 CFR Table 2 to Subpart GGGGG of Part 63: Table 2 to Subpart GGGGG of Part 63—Control Levels as Required by § 63.7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES
- Subpart GGGGG—National Emission Standards for Hazardous Air Pollutants: Site Remediation
If your tank design capacity is . . . And the maximum HAP vapor pressure of the remediation material placed in your tank is . . . Then your tank must use . . .
1. Less than 38 m3 Less than 76.6 kPa Tank Level 1 controls under § 63.7895(b).
2. At least 38 m3 but less than 151 m3 Less than 13.1 kPa Tank Level 1 controls under § 63.7895(b).
3. 151 m3 or greater Less than 0.7 kPa Tank Level 1 controls under § 63.7895(b).
4. at least 38 m3 but less than 151 m3 13.1 kPa or greater Tank Level 2 controls under § 63.7895(c).
5. 151 m3 or greater 0.7 kPa or greater Tank Level 2 controls under § 63.7895(c)